CERTIFICATION SYSTEM
From material function to market-ready documentation.
The referenced HALOGLAS certification page groups the material evidence into six buyer-facing areas: far-infrared emissivity, US FDA food-contact migration, EU LFGB food-contact review, China GB 4806.5 migration safety, ISO skin-contact biocompatibility, and photocatalytic antimicrobial performance.
Far-infrared spectrum and emissivity data for material positioning and technical storytelling.
FDA, LFGB, EU, and GB testing references for drinkware, tableware, and related product lines.
Skin irritation and sensitization results for jewelry, accessories, and wellness hardware programs.
REPORT INDEX
Technical evidence matrix.
Summaries below are rewritten for website use from the public certification pages. Full report copies should be supplied during RFQ or distributor qualification review.
FAR-INFRARED PERFORMANCE
Documented far-infrared emission profile.
HALOGLAS far-infrared glass tableware is reported with a normal total emissivity of 0.88 at 40 C. The spectrum covers 2.5-25 um, with a reported peak at 8.05 um and strong output across the 7-10 um band. For product teams, this creates a concise technical basis for positioning the material as a functional glass platform rather than a purely decorative glass.
SAFETY AND MARKET ACCESS
Food-contact and skin-contact evidence.
Food-contact evidence covers US FDA lead/cadmium leaching, EU/German LFGB sensory and heavy-metal migration, and China GB 4806.5-2016 migration testing. Skin-contact evidence includes closed-patch sensitization and repeated-exposure irritation tests using ISO 10993-aligned methods.
Reported values are below the relevant US, EU/German, and China regulatory thresholds for the submitted HALOGLAS samples.
Published summaries report no sensitization response and negligible irritation for the tested HALOGLAS extract.
ANTIMICROBIAL CAPABILITY
Visible-light photocatalytic antimicrobial testing.
Antimicrobial testing was presented under GB/T 30706-2014 using bright and dark condition comparisons. The public summaries report strong total antibacterial performance against E. coli and qualified antibacterial performance against S. aureus, with more moderate inhibition for Candida albicans.
REPORT DOWNLOADS
Certification report library.
Download the public test reports used for the technical evidence summary. Files are hosted locally for buyer review, supplier qualification, and internal material approval workflows.
HALOGLAS FIR Test on Bowl
Report ref. WT-HW-01087. Far-infrared emissivity and spectrum test summary for HALOGLAS glass tableware.
FDA Leachable Pb / Cd Test
Report ref. TSNHL26000834001 / TJHL2603001648CW. US FDA lead and cadmium leachable review.
Skin Sensitization & Irritation Test
Report ref. 2026FM04534R01E. ISO-aligned skin sensitization and irritation testing for submitted HALOGLAS samples.
LFGB Leachable Pb / Cd Test
Report ref. TSNHL26000834201 / TJHL2603001649CW. EU and German LFGB sensory and heavy-metal migration review.
GB Migration Pb / Cd Test
Report ref. TSNHL26000522501 / TJHL2602001052CW. China GB 4806.5-2016 migration safety review.
Antimicrobial E. coli Test
Report ref. 2026SP01074R01E. Visible-light photocatalytic antimicrobial performance against E. coli.
Antibacterial Candida Albicans Test
Report ref. 2026ZD00436R01E. Visible-light photocatalytic inhibition test against Candida albicans.
Antimicrobial S. aureus Test
Report ref. 2026SP01074R02E. Visible-light photocatalytic antimicrobial performance against Staphylococcus aureus.
Request the certification pack.
Ask for report copies, TDS, application guidance, and market-specific documentation during sample or bulk RFQ review.